The 5th percentile Thor female frontal impact dummy was designed,
developed and manufactured under funding from the NHTSA.  The
dummy's anthropometry is derived from UMTRI studies. The first
prototype was delivered to the NHTSA in 2004.  A list of features of the
dummy are available in the page titled "Literature".  Many of the
design features of the Thor NT dummy are included in this dummy,
and some more advanced features in this dummy can be used on the
NT dummy.   GESAC manufactures, sells and services this dummy.  

Some technical details are provided below.  
5th Percentile Female Advanced Frontal Impact Dummy
5th Percentile
Advanced Female
Frontal Impact Dummy
Sensor Type
Location
Measures
Accelerometer array [9]
Head
Linear accel,
compute ang. accel
Load cells [5]
Face
Uniaxial Fz load at 5
face locations
Load cell
Rear neck
spring
Compressive load on
rear neck spring
Load cell
Front neck
spring
Compressive load on
front neck spring
Load cell
Upper neck
Fx, Fy,Fz, Mx, My, Mz
Rotary potentiometer
O-C joint
Head - Neck angle
Load cell
Lower neck
Fx, Fy,Fz, Mx, My, Mz
Tri-Axial accel
T-1
Ax, Ay, Az
Tri-Axial accel
Thorax CG
Ax, Ay, Az
CRUX [4]
Thorax
3-D deformation of
ribs.
Uni-axial accel
Upper
Abdomen
Penetration into
upper abdomen
Load cell
T-12
Fx, Fy,Fz, Mx, My, Mz
Tri-axial accel
Pelvis CG
Ax, Ay, Az
DGSP [2]
Lower
Abdomen
3-D deformation of
abdomen at 2 points
Load cell
Pelvis
basin
Left acetabular
loads, Fx, Fy, Fx
Load cell
Pelvis
basin
Right acetabular
loads, Fx, Fy, Fx
Load cell
Femur
Left femur, Fx, Fy,
Fz, Mx, My, Mz
Load cell
Femur
Right femur, Fx, Fy,
Fz, Mx, My, Mz
Segment
Mass, Kg
Head
 
Neck
 
Thorax
 
Pelvis
 
Upper leg
 
Lower leg
 
Foot
 
Upper arm
 
Lower arm
 
Total